Anchor drive set-up (two speed models), 6 pengo revtrak manual, 64 b figure 3d – Pengo RevTrak User Manual

Page 16: Drawn by, Date checked by

Advertising
background image

6

PENGO RevTrak Manual

LBS

Kg

0.00

Figure 2D

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:4

SHEET 1 OF 1

HEAT TREAT

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

THIRD ANGLE PROJECTION

C

DATE

CHECKED BY

C

Figure 2D

REV

NOTE: The following instruction steps are for PENGO RT series Drives only.

ANChOR DRIvE SET-UP (TwO SPEED MODELS)

Remove bail housing to expose hydraulic motor.

Note: before removing the bail housing scribe a line from the housing to the gearbox to indicate a reference mark

for re-assembly.

1

Figure D

Figure 2D

Remove three threaded plugs from the hydraulic

motor to install the transducers (6):

. Remove the plug from the elbow located on the

pressure side of the hydraulic block.

2. Remove the plug from the tank side of the hydraulic

block.

3. Remove the plug from the sequence port located near

the top of the motor. See figure 1D.

Once the plugs have been removed install three pressure

transducers (6) in the three exposed ports as shown.

Note: use of Teflon tape on the threads of the transducers

is highly recommended to reduce potential leaks.

2

Secure wire harness (4) to the transducers (6).

. Clip harness end marked “

Pressure” to the

pressure side transducer.

2. Clip harness end marked “

Tank” to the tank side

transducer.

3. Clip harness end marked “

Sequence” to the pressure

transducer located near the top of the motor.

See figure 2D.

3

Fasten controller (3) to the bail housing as shown

in figure 3D with bolts (17) and nuts (18). The bail

housing will have existing holes typically located

on the front face of the housing.

4

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 1D

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:1

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

Elbow located under

Pressure Block

6

6

6

4

B

Figure 3D

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 3C

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:1

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

3

7

8

Pressure

Tank

Sequence

Note:

Do not remove the entire

port plug. Only remove the

small threaded plug from

the middle.

Advertising