REvTRAK OPERATION

OPERATING PROCEDURES

SD CARD PREPARATION

. Ensure Display unit and Logger have power. Power

can be supplied by either the prime movers battery or

by connecting into the auxiliary port located inside the

prime movers cab. The display should be visible as

well as green lights on the logger.

2. Open the top lid of the Logger to install SD card.

Do

not open lid by force! See figure 1E

3. Install the provided SD card into the Logger. The

Logger will not record unless a SD card is installed.

The SD card will only install into the Logger one way,

refer to the arrow on the SD card.

3-A. The SD card must be pre loaded with the file

CONFIG.CFG. The SD card provided with the RevTrak

system comes pre loaded with the CONFIG.CFG file. If

additional SD cards are used with the RevTrak system

this configuration file

MUST be loaded on the SD card

before use.

Use 2GB SD cards only.

3-B. It is important, that the SD card file format is

FAT.

This format is the only format the logger will recognise.

If you encounter an error with the SD card it could be

the file format.

wARNING

Before operating, always ensure that

all electrical connections are tight and

free from potential hazards and or

entanglement during operation.

Figure E

DISPLAY LOCATION / INTERFACE

. Chose a convenient location to mount the RevTrak

display. The location should not interfere with safety

devices (lap bar) or compromise the operators visibility.

The location should also allow the operator to easily access

the display to start and stop the data recording function.

-A. The display can be mounted to a glass surface using

the two suction cups provided with the RevTrak. (See

figure 1A for suction cup installation) When using the

suction cups be sure to lightly moisten the cups for better

suction against the glass.

-B. The display can also be hard mounted to any surface

using hardware (not included). This method is only

recommended if the location is to be permanent.

DATA RECORDING OPERATION

. Select the Drive model by pressing the MDL button.

This will bring up the model selection screen. This screen

will allow the operator to select from the different models

of Pengo Revolution Series Anchor Drives.

Note, Ensure the correct Drive model is

selected. The RevTrak system does not automatically

select the model. This is set by the operator.

To select, turn the dial to scroll through the different models

and push in the dial to select the desired model. Once the

desired model is selected push the ESC button to return

to the main display screen.

2. To start recording the installation data the operator must

push the button on the display located directly under the

“REC” on the display. (When the “REC” button is pressed

the logger will start recording the torque, differential

pressure, date, time and Drive model)

3. When the “REC” button is pressed the word “Recording”

will appear below the numerical torque value. When the

“REC” button is pressed for a second time the logger will

stop recording data and the word “RECORDING” will no

longer be displayed.

Note: It is recommended that when recording data the operator start and stop the recording with each

anchor / pier. Allowing the RevTrak system to continuously record for extended periods of time will make

interpreting the exported data difficult.

NOTE: The system must be powered on and then powered off on the first

time of use. This will set the system and all components. This step is only

necessary on the first time of use.