Anchor drive set-up (rs-12 single speed model), Pengo revtrak manual 5, Figure 5c – Pengo RevTrak User Manual

Page 15: 6 4 figure 4c

Advertising
background image

PENGO RevTrak Manual 5

NOTE: The following instruction steps are for PENGO RS series Drives only.

Connect wire harness (4) to controller (3). Align

the pins and complete the connection with a /4”

wrench. See figure 4C.

Note: Ensure that the wire harness connection is solid and

not binding or pinched.

5

Determine which cable (7 or 8) the 0’ or 20’ section

is necessary to sufficiently reach from the Drive to

the area in which the Display will be positioned.

Connect the Drive wire harness to the chosen cable.

Connect the other end of the cable to the Display wire

harness.

Note: Ensure that the cable has enough “slack” to allow

for full range or movement . Most cables can be run next

to the hydraulic hoses.

7

Arrange the cable connection end of the harness

in a way that will be easily accessible to connect to

the lead cables (7 and or 8). Suggested orientation

is to route the harness end through the top side of the bail

housing.

6

ANChOR DRIvE SET-UP (RS-12 SINGLE SPEED MODEL)

Figure 5C

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 5B

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:8

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 5B

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:4

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

4

6

This connection is only necessary

if an auxiliary power port is not

available. This is for battery

supplied power only.

6

4

Figure 4C

TOLERANCES UNLESS OTHERWISE SPECIFIED

.X .1 [2.54 .XX .03 [.76] .XXX .010 [.25] ANGLE 1 DEG.

LBS

Kg

0.00

Figure 4B

THIS DRAWING IS THE PROPERTY OF PENGO 500 E.

HIGHWAY 10 LAURENS, IA. 50554. NO USE THEREOF SHALL

BE MADE OTHER THAN AS A REFERENCE FOR PROPOSALS

SUBMITTED BY PENGO CORPORATION AND/OR FOR JOBS

BEING EXECUTED IN CONFORMITY WITH SUCH PROPOSALS

HAVE BEEN ACCEPTED. UNLESS THE CONSENT OF SAID

PENGO CORPORATION HAS BEEN PREVIOUSLY OBTAINED.

NO PART OF THIS DRAWING SHALL BE COPPIED OR

DUPLICATED OR IT'S CONTENTS DISCLOSED.

DRAWN BY

MATERIAL

TITLE:

SIZE

REV

SCALE: 1:8

SHEET 1 OF 1

HEAT TREAT

THIRD ANGLE PROJECTION

B

DATE

CHECKED BY

4

3

Complete connection by tightening

bolt. (/4” wrench)

The power source for the display will be determined

by the prime mover. It can be powered by an

auxiliary port commonly known as a “ cigarette light

port” or connected directly to the battery with the use of

the secondary power cord (6).

Battery Connection:

Connect the auxiliary plug on the display wire harness

(4) into the secondary power (6) cord once a battery

connection has been made. See figure 5C.

Note: Battery terminal ends are not provided on the

secondary power cord.

8

Advertising