Section 3. Operation

Remote Programming

21

Programming

Output

Current with

a 0-10k

Resistance

1. Select remote current programming by external resistance by moving the rear

panel switch S1-3 (remote current program select) to the ON (closed) position.

Or, connect J5 pin 8 (remote current program select) to J5 pin 6 (auxiliary
ground). As these two control functions are wired in parallel, they function as a
logic OR.

2. Set rear panel switch S1-2 (resistive current program select) to the ON (closed)

position.

3. Connect a variable resistance between J5 pin 16 and either pin 4 or pin 5

(program return).

4. Adjust the resistance from 0-10k

Ω to vary the power supply current limit from

0-100% of rated output. You may set the power supply's output voltage using
another source or the front panel voltage control.

Programming

with a Fixed

+10V

Reference

The APG Interface J5 connector provides a +10 V reference output at pin 20 for
applications which require a fixed output voltage and/or current limit. The current
from this output must be less than 10 mA.

To program output voltage:

1. Connect resistor A between J5 connector pin 20 (+10 V reference out) and pin

17 (voltage program).

2. Connect resistor B between pin 17 (voltage program) and either pin 4 or 5

(program return).

To program current limit, follow the procedure used to set up for programming
output voltage, substituting pin 16 (current program) for pin 17.

Figure 3.1 Programming with a Fixed +10V Reference

V

OMAX

R

B

V

o

= --------------

R

A

+ R

B

Where:

V

o

= programmed output of power supply

V

o

MAX

= rated maximum output of power supply

R

A

+ R

B

> 1k

J5-20

J5-17

J5-4

+10 V

Vpgm

R

A

R

B

Advertising