The simplest way to connect to other hosts (not PC compatible) or
terminals is:

Printer

Terminal/Host

Pin 2- RxData

………

TxData

Pin 3- TxData

………

RxData

Pin 5- Ground

………

Ground


In general, as long as the data quantity is not too large and you use
Xon/Xoff as flow control, it will be problem free.

Baud rate:

1200, 2400, 4800, 9600(default), 19200, 38400,
57600,115200 bauds. (Programmable by command)


Data format: always 8 data bits, 1 start bit and 1 stop bit.


Parity:

always non parity


Handshaking:

XON/XOFF as well as CTS/RTS (hardware flow

control).


If you run an application with the bundled printer driver under
Windows and use the serial port, you should check the above
parameters and set the flow control to "Xon/Xoff "or "hardware".