Connection to control terminal – Audio Enhancement TLD100 User Manual

Page 20

Advertising
background image

20

Connection to control terminal

Cable processing

Before connection, prepare the cable as shown in the
drawing at right.

Note:

• Stranded wire is highly recommended.
• Wire insulation must be removed.
• Do not use solder to tin the wire.
• The recommended maximum cable length is 15 m {49

feet}.

Connection of F1 CNT and F2 CNT terminals

An external device is connected between CNT and COM. These terminals are isolated from the internal circuit by a
photo coupler.

Connection of F2 ACK and PAGE MUTE terminals

An external device is connected between each terminal and GND. These terminals operate by closing their circuits. The
GND terminal is connected to GND in this unit. A set of “dry relay” contacts are recommended to activate these features.

F1 CNT
F2 CNT

COM

F1 CNT

COM

F2 CNT

COM

Circuit configuration

Photo coupler

← Max. 20 mA

External

device

Output format: Open collector, make output

Electrical specifications: Control voltage 30 V, control current 20 mA

F2 ACK
PAGE

MUTE

GND

F2 Acknowledge

GND

Page mute

GND

Short-circuit current

2 mA

External

device

Input format: Transistor input

Electrical specifications: Open voltage 5 V DC, short-circuit current 2 mA

Tightening torque: 0.2 N·m {0.14 lbf·ft}

(max.)

Suitable electric wire: AWG 28 - 14

7 mm±1 mm

{9/32 inches

±1/16 inches}

Circuit configuration

Advertising