About the coaxial cables – Audio Enhancement TLD100 User Manual

Page 25

Advertising
background image

25

About the coaxial cables

Use the following length and type of coaxial cable to connect the infrared receivers and the infrared sensors.

• Length of coaxial cable: Less than 20 m {66 feet}
• Type of coaxial cable: RG-6U

When connecting a single Infrared Sensor (EDS-07)

Make a connection so that the length between the Infrared Sensor (EDS-07) and this unit is kept within a range of 20 m
{66 feet}.

When connecting two or more Infrared Sensors (EDS-07) by utilizing the Infrared

Sensor Coupler (AE-DCF)

"Coaxial cable: A" : the coaxial cable length from the Infrared Receiver to the Infrared Sensor Coupler.
"Coaxial cable: B to E" : the coaxial cable length from the Infrared Sensor Coupler to each Infrared Sensor.

• The total length of the longest cable length among "Coaxial cable B-E" plus "Coaxial cable A" should be kept

under 20 m {66 feet}.

[Good example]

Coaxial cable length: A = 5 m {16.4 feet}, B = 8 m {26 feet}, C = 4 m {13 feet}, D = 6 m {20 feet}, E = 10 m {33 feet}

Total cable length: A: 5 m {16.4 feet} + E: 10 m {33 feet} = 15 m {49.2 feet}

This is less than the limit 20 m {66 feet}, therefore, there is no problem.

[Bad example]

Coaxial cable length: A = 15 m {49.2 feet}, B = 8 m {26 feet}, C = 4 m {13 feet}, D = 6 m {20 feet}, E = 10 m {33 feet}

Total cable length: A: 15 m {49.2 feet} + E: 10 m {33 feet} = 25 m {82 feet}

This is over the limit 20 m {66 feet}, therefore, there is a problem with a length.

Note:

• Check the specifications of both the F-connector and the coaxial cable to ensure that they match before assembling.

Follow the instructions of the F-connector to assemble securely.

• In order to make the connections secure, use screw-type F-connectors.

TLD100

EDS-07

20 m {66 feet} or less

AE-DCF

EDS-07

EDS-07

EDS-07

TLD100

EDS-07

Coaxial cable: B

Coaxial cable: C

Coaxial cable: E

Coaxial cable: A

Coaxial cable: D

Advertising