Installation

(for qualified installers only)

15

Travis Industries

4140611

100-01385

Minimum Framing Dimensions - Rear Vent Configuration

Route the

electrical line to

a position to the

left rear of the

fireplace.

Vent Clearances 8" (203mm) dia. Vent:

1" (25mm) to the sides, 1" (25mm)

below, and 3" (76mm) above the vent to

combustibles.

Included Firestop (required)

Part # 93006094

Center of Rear Vent

30-3/4"

781mm

38"

965mm

41-1/4"

1048mm

38-1/2"

978mm

20-3/4"

528mm

HINT: place the fireplace so the center

line is at least 5" (127mm) from both

vertical framing members at the rear (this

allows the vent to pass through the

framing without modfications)

25-3/4"

654mm

Minimum enclosure height = 38-1/2" (978mm)