20 installation, Outdoor fireplace installations – Avalon Firestyles 864 TRV GS2 Installation User Manual

Page 20

Advertising
background image

20 Installation

(for qualified installers only)

Travis Industries

4140611

100-01385

Outdoor Fireplace Installations

Travis Industries Inc. gas-fired fireplaces are
suitable for installation into outdoor areas
protected from direct water impingement. In
addition to maintaining listed mantel and
combustibles clearances, a rain protection
overhang factor of 1/2 shall be constructed to
the front and to each side of installed
appliances (see the illustration to the right). All
wiring connections to line power shall be in
accordance with outdoor requirements of
NECA NFPA 70.

Warnings Regarding Tempered Glass

This fireplace uses tempered glass which is
susceptible to thermal shock. Take care to
prevent water from contacting the fireplace,
especially if it is hot.

A

B

Side of

Fireplace

The overhang (A) must extend at least 1/2 the roofline height

(B). Height is measured from the base of the fireplace.

For example: if the rooline (B) is 8' above the base of the

fireplace, the overhang (A) must be at least 4'.

Advertising
This manual is related to the following products: