Installation

(for qualified installers only)

31

Travis Industries

4140611

100-01385

Rear Vent Configuration with Horizontal Termination (with vertical rise)

 The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and

diffuser positions.

 Up to four elbows (45° or 90°) may be used.
 Only one horizontal elbow may be used.

5 feet (1.5 m)

0 feet

0 feet

5 feet (1.5 m)

0 feet

20 feet (6 m)

20 feet (6 m)

5 feet (1.5 m)

10 feet (3 m)

5 feet (1.5 m)

10 feet (3 m)

0 feet

15 feet (4.5 m)

20' max (6 m)

10 feet (3 m)

15 feet (4.5 m)

15 feet (4.5 m)

20' max (6 m)

10 feet (3 m)

15 feet (4.5 m)

22' max (6.7 m)

22' max (6.7 m)

Exhaust Restrictor # 4

Intake Restrictor # 2

Diffuser Position # 2

Exhaust Restrictor # 1 (stock)

Intake Restrictor # 1 (stock)

Diffuser Position # 1 (stock)

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2