34 installation, Top vent configuration with vertical termination, For qualified installers only) – Avalon Firestyles 864 TRV GS2 Installation User Manual

Page 34

Advertising
background image

34 Installation

(for qualified installers only)

Travis Industries

4140611

100-01385

Top Vent Configuration with Vertical Termination

 The termination must

fall within the shaded
area shown in the chart.
Use the indicated
restrictor and diffuser
positions.

 Up to four elbows (45°

or 90°) may be used.

 Only one horizontal

elbow may be used.

 May use 8" (203mm) or

6-5/8" (168mm)
diameter vent (see
page for 25 details).

Exhaust Restrictor # 4

Intake Restrictor # 2

Diffuser Position # 2

This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.

This is considered a
vertical elbow

Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).

H1

H2

5 feet (1.5m)

0 feet

0 feet

5 feet (1.5m)

0 feet

20 feet (6m)

20 feet (6m)

5 feet (1.5m)

10 feet (3m)

5 feet (1.5m)

10 feet (3m)

0 feet

15 feet (4.5m)

20' (6m) max

10 feet (3m)

15 feet (4.5m)

15 feet (4.5m)

20' (6m) max

10 feet (3m)

15 feet (4.5m)

40' (12m) max

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)

40' (12m) max

25 feet (7.5m)

30 feet (9m)

35 feet (10.5m)