26 installation – Avalon Firestyles 864 TRV GS2 Installation User Manual

Page 26

Advertising
background image

26 Installation

(for qualified installers only)

Travis Industries

4140611

100-01385

Approved Vent

 Rear vent configurations use 8" (203mm) diameter Simpson Dura-Vent Model Direct-Vent Pro (or

GS)*.

 Top vent configurations use 8" (203mm) or 6-5/8" (168mm) diameter Simpson Dura-Vent Direct-Vent

Pro (or GS)*. If using 6-5/8" (168mm) diameter vent, attach the 8" (203mm) to 6-5/8" (168mm)
reducer (Travis part # 98900165) to the fireplace.
NOTE: When using 6-5/8” (168mm) diameter vent, make sure to accommodate the 3” (76mm)
clearance above the vent for the first 48” (1219mm) of rise (see vent clearances on page 25).
Standard firestops do not include this clearance.

* Other vent may be approved with this fireplace. Check with the vent manufacturer for details.

 Always use the high-wind cap (or high-wind sconce cap, part # 58DVA-HSCH or 46DVA-HSCH).
 Installation instructions for Simpson Dura-Vent may be found at www.duravent.com

Vent Installation

 Slide the vent sections together and turn 1/4 turn until the sections lock in

place.

 Screws are not required to secure the vent. However, three screws may be

used to secure vent sections together if desired.

 High temperature sealant is recommended at the appliance starter section

connection (use high-temperature silicone or Mill-Pac®).

 If disassembly is required, at time of re-assembly check to see if the vent

creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.

 Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel
 Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape)

6-5/8" (168mm) Diameter Vent

Reducer - # 98900165

Advertising