Installation, Facing detail, For qualified installers only) travis industries – Avalon Firestyles DVL Fireplace EF-2003 to 2007 User Manual

Page 12

Advertising
background image

1 2

Installation

(for qualified installers only)

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

Facing Over 1" Thick

W A R N I N G

:

Faces that attach with latch-hooks
(Avalon Rosario, Avalon Cambridge,
Avalon Salish Bay, Avalon Rawhide,
Lopi Discovery, Lopi Heritage Bay, FPX
Architectural Faces (all styles),
require a 5/8” gap above the
f a c e

for face installation and removal.

If the facing material is over 1" thick
(e.g. brick, river rock), install the facing
around the perimeter of the face. You
may wish to make a facing support (see
the illustration to the right). If using an
arch face, you may wish to order the
optional set-up face:

34 Arch Set-Up Face is available from
Travis Industries (Part # 98500694)

Artisan faces vary in size. Use the face
being installed to create a template.

Rectangular Faces

Make a facing support using 2x4’s. It

should be 1/8” larger than the finished

face. NOTE: The bottom of the face is

1” above the base of the fireplace.

1”

Note: if using a brick hearth, the fireplace will need to be raised to accommodate the 1” gap betwen the
face and the base of the fireplace. For 2-1/2” thick brick this works out to approximately 1-1/2”.

The brick facing must meet the same requirements
listed in “Facing Requirements”

Center

Line

Arch Faces

Use the optional

Arch Set-Up Face

available from Travis

Industries.

Facing Detail

Access Door

1"

Face

1"

Glass

Air Space

Do not tuck facing under the faceplate on the bottom The

3/8"

(approx.) gap below the access door is required for the door to open. You

may tuck facing under the sides and top, but not on the bottom.

SIDE OVERLAP: To calculate the side overlap,

subtract 32-7/8" from the face (see "Face

Dimensions" on page 13) width and divide by 2.

TOP OVERLAP: To calculate the top overlap,

subtract 25-3/8 from the face height (see "Face

Dimensions" on page 13) - for arched faces, see

the "Dimensions" on page 6 for other details.

Approx.

3/8"

To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing directly
next to the fireplace. See the illustration below.

Fireplace

1"

1/2" Drywall

1/2" Concrete Board

3/8" Tile

This 2x4 is recessed 3/8"
to make a flush facing

Fireplace

1/2" Drywall

1/2" Concrete Board

3/8" Tile

The tile overlaps the drywall
for an overlap facing

Faceplate

1"

TOP
VIEW

Faceplate

Advertising