7

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

Installation Warnings:

Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.

This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.

This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).

In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing
only after the home is site located.

The fireplace is designed to operate on natural gas, or propane (LP).

All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.

Notify your insurance company before hooking up this fireplace.

The requirements listed below are divided into sections. All requirements must be
met simultaneously. The order of installation is not rigid – the qualified installer
should follow the procedure best suited for the installation.

Packing List

Propane Conversion Kit

Log Set

Glass Latch Key (to un-latch glass frame)

Firestop

Fireback Clips (for Ceramic Firebacks Only)

Additional Items Required

Faceplate

Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)

Gas Line Equipment (shutoff valve, pipe, etc.)

Electrical Equipment (min. 14 gauge, grounded line)

Installation Overview

Non-combustible facing

(see the section "Facing

Requirements")

See the section

"Acceptable Vent

Lengths"

See the section "Horizontal

Termination Requirements"

See the section

"Gas Line Installation"

See the section

"Electrical Connection"

See the section

"Mantel Requirements"

Insulation must not fill

the 1" clearance

around the back and

sides of the fireplace.

See the section "Fireplace

Placement Requirements"

6" Min.

See the section

"Vent Requirements"

See the section "Minimum

Framing Dimensions"

See the section

"Hearth Requirements"

Drywall

Nail

Down

Plate

This grommet and hole is for

thermostat wire (on both sides)

Side

Wall