Installation

(for qualified installers only)

9

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

Corner Installations

A typical 45° installation
uses the minimum framing
dimensions shown in the
illustration to the right
(NOTE: all clearances still
apply).

19-3/8"

1" Standoffs

Min. 1" Clearance to

Fireplace Enclosure

47-5/8"

13-3/4"

14-3/4"

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(250 Lbs.) and vent.

The fireplace may not be raised so as to place the ceiling within 36" of the base of the fireplace.

Raised fireplace

Raised fireplace with
raised hearth.

Raised
Platform

Nail the nail down plates to the floor
(or raised platform)

Raised Hearth

Hearth

Raised
Platform