Safety Label

4 1

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

The safety (listing) label is on a
plate chained to the gas
control valve. A copy of the
safety label is shown to the
right.

Travis Industries, Inc.

DVL Z.C. Fireplace

Vented Gas Fireplace Heater (Direct V

ent)

Tested to:

ANSI Z21.88-2002 “V

ented Gas Fireplace Heater” and UL

307b-1995 “Gas Burning Heating

Appliances for Manufactured Home

s”.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,

ANSI Z223.

1/NFP

A

54.

Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, T

itle 24 CFR

,

Part 3280.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,

the optional

factory conversion kit must be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,

permanently located, manufactured (mobile) home where not prohibited by local codes. See owner

’s manual for details. This appli

ance is

not convertible for use with other gases, unless a certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s installation instructions.

Use only

approved coaxial direct vent system to vent this appliance to the exterior

. See owner

’s manual for approved brands of venting.

W

ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to th

e owner

’s

information manual provided with this appliance. For assistance or additional information consult a qualified installer

, servic

e agency or

the gas supplier

.

VENTED GAS FIREPLACE HEA

TER – NOT FOR USE WITH SOLID FUEL

CAUTION:

Hot while in operation. Do not touch. Severe burns may result.

Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away

.

Do not operate this appliance with glass removed, cracked or broken. Replacement of the

panel(s) should be done by a licensed or qualified service person.

4800 Harbour Pointe Blvd. SW Mukilteo, W

A

98275

Minimum Clearances to Combustibles

Faceplate to

Adjacent W

all
. . . . . . . . . . .

6”

Hearth Extension in Front - 12”, 0” if Fireplace Raised 3”

W

ood Floor Beneath Fireplace

. . . . . . . .

0”

Hearth Extension to Sides of Faceplate

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

0”

Back to enclosure

. . . . . . . . . . . . . . . . . . .

1”

Sides to enclosure

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . .

1”

Top of enclosure

Faceplate to Mantel (with 8” Mantel)*

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24”

to Bottom “Base” of Unit

. . . . . . . . .

54.5”

Faceplate T

op Facing (with 8”

Mantel)*

. . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

18”

Flue V

ent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3” T

op / 1” Side and Botto

m

* See Owner

’s Manual For

Additional Mantel Clearances and Options.

FAN TYPE VENTED CIRCULA

T

OR – Blower Electrical Rating: 1

15 V

., 1.5

Amps, 60 Hz, 150 watts

L.P
.

N.G.

L.P
.
N.G.

Input Rate on “HI” (BTU/Hr)

............

40,000

40,000

Minimum Inlet Pressure (inches W

.C.)
...............

11”

5.5”

Input Rate on “LO” (BTU/Hr)

...........

29,000

24,500

Maximum Inlet Pressure (inches W

.C.)
..............

13”

7”

Main Burner Orifice (DMS)

..............

#55

#45

Manifold Pressure on “HI” (inches W

.C.)

..........

10”

3.5”

This appliance is equipped for installation at 0-2000 ft. .

For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.

See the owner

’s manual for information on making these changes.

Manufacture

2004

Jan.

Apr
.

Jul.

Oct.

Date:

2005

Feb.

May

Aug.

Nov

.

2006

Mar

.

Jun.

Sep.

Dec.

0500 (IGN)

Report No. 028-S-23b-5