Installation, Approved vent configurations, For qualified installers only) travis industries – Avalon Firestyles DVL Fireplace EF-2003 to 2007 User Manual

Page 20: Restrictor position, Measuring vent lengths

Advertising
background image

2 0

Installation

(for qualified installers only)

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

Approved Vent Configurations

Restrictor Position

Remove the face (if installed).

To Adjust the Restrictor:

To Access the Restrictor:

1

2

Determine the correct restrictor position (see the charts under
"Approved Vent Configurations" - the factory position is #1).
Lift up the adjustment plate and move it so the correct notch
falls into the slot on the adjustment bracket.

This restrictor is in position 1
(factory setting).

This restrictor is in
position 4 -

To adjust, lift the adjustment plate
and push it back.

WARNING: Use a glove to
protect your hand from burns.

Adjustment

Bracket

Adjustment

Plate

# 8

# 7

# 2

etc.

NOTE: position 5 is fully closed - positions 6 through 8 are not used.

Measuring
Vent
Lengths

NOTE:
All measurements
are for 8" diameter
vent.

Vent

Horizontal

Run

Vent

Height

3-1/2"

Side
View

1-3/4"

Vent Length
(2', 3', etc.)

NOTE:
Vent sections overlap
each other by 1-3/4"

42"

10-3/4" wide with

1-3/4" to

3-3/8" of overlap

Starter
Section

12-3/8"

3-1/2"

8"