Installation

(for qualified installers only)

1 7

Travis Industries

4041206

1 0 0 - 0 1 1 4 7

Mantel Requirements

The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed in this manual.

Combustible or Non-Combustible Mantels

Combustible or Non-Combustible Mantel

Mantel
Depth

Base of Fireplace

1”

Bottom of Faceplate

Face Height

(see “Face Dimensions” on page 13)

Face

Mantel

Clearance

(see table

below)

Mantel Clearance:

• Measured From Top of Faceplate

(see “Faceplate Dimensions” on page 13)

8" Max. Mantel Depth

10" Max. Mantel Depth

12" Max. Mantel Depth

Avalon Cambridge

15"

15"

15"

Avalon Craftsman

15"

15"

15"

Avalon Rosario

18"

20"

21"

Avalon Victorian Lace

16"

16"

16"

Avalon Victorian Lace with shield

16"

16"

16"

Avalon Rawhide

16"

16"

16"

Avalon Rawhide with shield

16"

16"

16"

Avalon Bungalow

26”

26”

26”

FPX 34 Arch & Artisan

24"

25"

26"

FPX 34 Arch & Artisan with shield

17.5"

18"

18.5"

FPX Metropolitan

24"

24"

24"

FPX Metropolitan with shield

16.5"

16.5"

16.5"

FPX Art Deco

19.5"

19.5"

19.5"

FPX Art Deco with shield

15"

15"

15"

FPX Neo-Classic

19"

19"

19"

FPX Neo-Classic with shield

15"

15"

15"

FPX Arts & Crafts

20"

20"

20"

FPX Arts & Crafts with shield

15"

15"

15"

FPX French Country

16"

18"

19"

FPX French Country with shield

15"

15"

15"

Lopi Discovery

16"

16"

16"

Lopi Wilmington

19”

19”

19”