Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual
Page 166
Data Structure Reference 5-7
C O D E 9 3 I N F O
SCAN1223.LIB only. The CODE93INFO data structure
c ontains 1223 scanner configuration information about Code 93
bar codes. To read these values, applications call
scnGetCode93Info; to set these values, they call
scnSetCode93Info.
typedef struct _Code93Info
{
unsigned char uchEnable;
unsigned char uchLength1;
unsigned char uchLength2;
} CODE93INFO;
Field
Description
uchEnable
Enable/disable the ability to scan Code 93 bar
codes.
Default: SCN_DISABLE
uchLength1
uchLength2
Specifies lengths (including check digits) for
Code 93 bar codes. You can s pecify one or two
lengths, a range of lengths, or that any length is
valid. Enter values as follows:
Option
uchLength1
uchLength2
1 Length
Value
0
2 Lengths
Higher Value
Lower Value
Range
Min. Value
Max. Value
Any length
0
0
Default: 4 (uchLength1) and 55 (uchLength2).