Time delay, 50t instantaneous overcurrent protection, Pickup – Basler Electric BE1-CDS240 General Information User Manual

Page 21: Setting range, Accuracy (50tp, 50tn), Accuracy (50tq), Accuracy, 50bf breaker failure protection, Delay timer, 50t instantaneous overcurrent protection -19

Advertising
background image

Time Delay

Setting Range ................................................................ 0.050 to 600 s

Accuracy ......................................................................... ±0.5% or ±1 cycle, whichever is greater

50T Instantaneous Overcurrent Protection
Pickup

Setting Range

5 Ampere CT ............................................................ 0.5 to 150 A

1 Ampere CT ............................................................ 0.1 to 30 A

Accuracy (50TP, 50TN)

5 Ampere CT ............................................................ ±2% or ±50 mA, whichever is greater

1 Ampere CT ............................................................ ±2% or ±10 mA, whichever is greater

Accuracy (50TQ)

5 Ampere CT ............................................................ ±3% or ±75 mA, whichever is greater

1 Ampere CT ............................................................ ±3% or ±15 mA, whichever is greater

Dropout/Pickup Ratio ...................................................... 95%

Time Delay

Setting Range ................................................................. 0 to 60 s

Accuracy

50TP, 50TN .............................................................. ±0.5% or ±¼ cycle, whichever is greater, Plus trip

time for instantaneous response (0.0 setting)∗

50TQ ........................................................................ ±0.5% or ±1 cycle, whichever is greater, Plus trip

time for instantaneous response (0.0 setting)∗

Trip Time for 0.0 Delay Setting

50TP, 50TN .............................................................. 1¼ cycles maximum for currents ≥ 5 times the

pickup setting. Three cycles maximum for a

current of 1.5 times pickup. Four maximum for a

current of 1.05 times the pickup setting.

50TQ ........................................................................ 2¼ cycles maximum for currents 5 times the

pickup setting. Three maximum for a current of

1.5 times pickup. Five cycles maximum for a

current of 1.05 times the pickup setting.

50BF Breaker Failure Protection
Pickup

Setting Range

5 Ampere CT ............................................................ 0.25 to 10 A

1 Ampere CT ............................................................ 0.05 to 2 A

SEF .......................................................................... 0.01 to 0.05 A

Accuracy

5 Ampere CT ............................................................ ±2% or 0.05 A, whichever is greater

1 Ampere CT ............................................................ ±2% or 0.01 A, whichever is greater

SEF .......................................................................... ±2.5% or 0.0025 A, whichever is greater

Time Delay

Delay Timer

Setting Range .......................................................... 50 to 999 ms

Accuracy .................................................................. ±0.5% or ±½ cycles; whichever is greater plus 2¼

cycles maximum for currents ≥ 5 times pickup

setting. Three cycles maximum for a current of 1.5

times pickup. Four cycles maximum for a current

of 1.05 times the pickup setting.

Reset Time ............................................................... Within 1¼ cycles of the current being removed

9365200990 Rev M

BE1-CDS240 General Information

1-19