2.3 Stock Solution Location

The solenoids rely on gravity to deliver nutrient and pH adjuster
into the nutrient tank. This means the stock solution tanks must be
above the nutrient mixing tank.

Align stock tanks above nutrient tank.

2.4 Solenoid System Set-up

The solenoids dose nutrient and pH adjuster to your tank at defined
intervals. These intervals are set in the on times and off times
found in the mode menu. The instructions for this are on page 23
and 24.

1. Drill a 18mm (3/4”) diameter hole near the bottom of each stock

tank. Ensure tank is empty before drilling. Remove drilling
residue (swarf) from the inside of the stock tank as this can clog
the solenoids.

2. Insert sealing grommet. Seal must be tight, a firm push
is required. See figure 1.

3. Insert the solenoids into the grommets.

4. Label tanks Nutrient A, Nutrient B and pH.

5. Secure breather tube to the top of the stock tank to avoid

spillage.

6. Place the feed hoses from the solenoids to the main tank.
To ensure even dosing of Nutrient A & B the tubes have to be

the same length. Nutrient A & B must drop into the tank, do
not mix before entering the water.

7. Test stock tanks for water tightness. Fill with nutrient or pH

adjust solution.

To prevent acid

damage on your

piping & fi ttings,

make sure you dilute

your acid solution to

5% or less.

2

Breather tube must be
higher than the nutrient
level inside the stock
solution tanks.

Tank

Figure 1 - sealing grommet

To gain greater control

of conductivity, mix

nutrient A and B as per

nutrient manufacturers

instructions.