3.7 Off Times

Off times are how long no dosing
will occur for. This gives your
system time to adjust/mix so
that the Dosetronic can measure
the changes it has made before
deciding if it needs to dose again.

1. Select Off Times

Press up and down keys to select
mode.

2. Select desired channel and

value to change
To programme Off Times select
the appropriate measurement.
Note: The selected value will
be brighter than other values
displayed.

3. Programme desired Off Times

Press (or hold down) the value
increase/decrease buttons
to change the value you have
selected.

Note: Start with long off times and
adjust from here

1

2

59.50

59.50

59.50

3

Nutrient

Of

f times

Please record
your values
here for future
reference.

Temperature

Of

f times

pH

Of

f times

3

Programmable from 0 - 59 minutes and 59
seconds in ten second steps