Specifi cations – Bluelab Dosetronic Solenoid Kit User Manual

Page 41

Advertising
background image

37

Version S1.3 : 260511

Bluelab Dosetr

onic Solenoid Kit

Bluelab Corporation Limited

Specifi cations

pH

Conductivity

Temperature

Medium

measured

Displayable units

Range

Resolution

Accuracy

Temperature Compensation

Calibration

Solution

Solution

Air or Solution

pH Scale

EC
CF

TDS (ECx500)

ppm (EC x700)

0.0 - 5.0 EC

0 - 50 CF

0 - 2500 TDS

0 - 3500 ppm

0 - 50 °C

32 - 122 °F

1 °C

1 °F

°C

°F

0.0 - 14.0 pH

0.1 pH

0.1 EC

1 CF

50 TDS

70 ppm

±0.1 pH

± 0.1 EC
± 1 CF

±1 °C

±1 °F

Yes

Yes

N/A

One, Two or
Three point

Yes

Not Required

(If ATC pH probe is connected)