WARNING: Do not touch the oven heating element.

WARNING: Make sure that the appliance is switched off before changing the light bulb to avoid electric shock.

5.3 ENVIRONMENTAL PROTECTION AND SAVING
• Using the oven between late afternoon and early morning helps to reduce demand peaks.
• Keeping the oven door gaskets clean and in good condition, so that they adhere to the door fi rmly, reduces heat loss.

6.FOR THE INSTALLATION ENGINEER

The appliance must be installed by a qualifi ed person, who must follow the instructions provided in this manual and in the
regulations:Law n. 46 of 05.03.1990 – Regulations on the Safety of Systems

6.1. Technical Data

Heating Element Power
Bottom heating element

1100 W

Top - bottom heating element

1100-1500 W

Fan heating element

2000 W

Oven light

15 W

Cooling fan (where installed) 22-26 W
Oven fan 25 W
Power supply voltage (50-60Hz) 230 V

Oven usable dimensions
Width mm. 411
Depth mm. 391
Height mm. 330
Volume l. 58

Usable dimensions of cavity in building-in cabinet
Height mm. 584
Width mm. 564
Depth mm. 550

6.2 Pre-Installation Procedures
• Unpack the appliance and recycle the packaging material in accordance with the relevant regulations.
• After unpacking, check the appliance for damage. If in doubt, do not use the appliance and contact a qualifi ed professional. (See

After-Sales Service).

• The packaging materials (plastic bags, expanded polystyrene, nails, etc.) must not be left within reach of children since they are

potentially hazardous.

• Check that the accessories are in the bottom of the packaging.
• Do not make improper use of the oven door handle during transport and installation.

6.3 Building-In the Oven
• In order to allow the product to be built in correctly, the cabinet must have the following characteristics:
- the panels next to the oven must be in heat-resistant material;
- if the cabinet is in veneered wood, the adhesive used must withstand a temperature of 100°C;
- when building-in the oven, whether the installation is under-counter or in a tall unit, the cabinet must have the dimensions stated

in Fig. 1 – page 17

• Place the oven in the cabinet and screw the 4 screws fully down, using the holes provided in the facia, visible when the oven door

is opened. Make sure that the screws are inserted towards the centre of the wood in the cabinet: (see Fig.1-3-page 17). Before fi xing
the screws, also ensure that the oven is correctly aligned with the fl oor with the aid of a spirit level.

• An opening in the top of the tall unit, or a 10 mm gap above the oven surround, should be provided to ensure adequate ventilation.

(see Fig. 1 - page 17).

• If the oven is to be installed close to another appliance, check that there is no interference between the two devices when in ope-

ration.

• Once the appliance has been built in, no contact with electrical parts must be possible.

6.4 Connecting to the electrical mains
For direct connection to the mains, a mains cut-off device with a contact breaking gap that ensures complete disconnection in category
lll overvoltage conditions must be provided, in accordance with the installation rules.
WARNING: The plug must be reachable when the appliance is installed.

Useful information for the installation engineer:
• the green-yellow coloured wire must be used to make the earth connection;
• the blue wire for the neutral;
• the brown wire for the live connection;
• the cable must not touch hot surfaces with a temperature over 75°C;
• if the cable is replaced, the new one must be of H05RR-F or H05V2V2-F type of suitable gauge (see Fig. 2 – page 17);