Display option 1-5 (lottery displays only), Display status – Daktronics Remote Control System RC-100 User Manual

Page 32

Advertising
background image

26

DataMaster Applications

Display Option 1-5 (Lottery Displays Only)

Select a DISPLAY OPTION to set the position of the decimal for each lottery display line.

Display

Action

L = current line

Press <ENTER> to set the display option or press
<CLEAR> to exit the menu.




L = current line







The current configuration is shown on the bottom line of
the LCD. Press the down arrow key <

> to select one of

the following values:

$000 (default)
$00.0
$0.00

Note: If the wrong configuration is selected for the display
being used, the value may not be displayed correctly.

Press <ENTER> when finished.


A screen will appear asking to confirm the selection.
Press <ENTER> again to update the display option.

Display Status

Select DISPLAY STATUS to view information about the display.

Display

Action

Press <ENTER> to get the display status or press
<CLEAR> to exit the menu.

Press <ENTER> again and the LCD will show the
following display status items:

Driver Firmware Version

Current Day/Time

Last Reset Time

Current Temp

Temp Sensor Offset

Dimming Level

Dimming Mode

Temp Sensor Status

Light Sensor Status

COM1 Device

Timing Reference

Press <CLEAR> to return to normal operation, or press
<ENTER> to access two additional display settings:
Display Passcode and Detect Clients.

DI SPLAY OPTI ON L
ENTER TO EDI T

DI SPLAY OPTI ON L
$ OOO }

DI SPLAY $ OOO
ENTER TO UPDATE

DI SPLAY STATUS
ENT TO SELECT

DI SPLAY STATUS
GET STATUS?