MODEL 320 - System Operation:

1

Turning ON the Scale:

To Zero-Balance the Scale:

Step 1) Press [ON].

Step 1) Press the [NET/GROSS] key and

A brief message is displayed (such as

"HELLO").

The scale enters

GROSS

weighing

mode. Pressing

[ON]

a second time during

normal system operation starts the self test.

A warm up period of ten to fifteen minutes
provides the most accurate readings. If the
scale is holding a load for a long period of
time (ex. overnight), the weight displayed may

The ZERO/BALANCE will "balance off"

vary because of zero shift created by changes

trailer, bin, or platform weight.

in temperature. This does not affect the
accuracy of the scale.

"ZERO" is displayed to show completion of

For example, if the system was loaded with

GROSS mode.

1000 Lbs, it might read 1200 Lbs the following
day. The change in temperature "zero shifted"

Pressing only the [ZERO] key will cause the

the

ZERO/BALANCE

from 0 Lbs to 200 Lbs.

message "TO ZERO/BALANCE PRESS

When unloading the scale, the display will

NET/GROSS - THEN ZERO" to be displayed.

count from 1200 to 200 Lbs for a total of 1000
Lbs.

If the supply power is below the "low battery

Turning OFF the Scale:

"INDICATOR CANNOT BE ZE-

Step 1) Press [OFF].

AGE" is displayed. The message "LO BAT" is

within three seconds,

Step 2) press the [ZERO] key.

the step and the scale is then placed in the

threshold" (10.5 Volts), the message

RO/BALANCED - LOW BATTERY VOLT-

periodically shown on the display (approx.
every five seconds) to alert the operator of the
low battery condition.

Loss of power does not affect the
ZERO/BALANCE or "Setup/Calibration"
values.