MODEL 320 - System Operation:

15

Step 2) Then use the numeric keypad to

counter every time the weight moves out of

identify the recipe number to be erased.

the tolerance window. If enabled, "motion

Step 3) Press the [ZERO] key.

Step 4) Press and hold the [ZERO] key, then

with the weight value. During this time the

press the [ON] key to erase the recipe.

scale WILL NOT auto-advance. This allows

Continue holding both keys until the indicator

the operator the opportunity to remove the

beeps and displays the message "RECIPE XX

excess weight. If the additional weight for the

ERASED".

ingredient is acceptable, press either [PRINT]

Step 5) Press [PROGRAM] to exit the "recipe

additional weight.

programming mode" and enter the weighing
modes.

To Change the Tolerance:

To erase all recipes, Continue steps 1 through
4 until all the recipes have been erased.

Step 1) To enter the "Long Form Setup Mode"

Using the Auto Advance Feature:

both keys until the indicator beeps and the

The auto advance feature allows for hands

by the current pre-alarm weight. The "CAL"

free operation of programmed recipes. The

annunciator will be flashing.

indicator prints and advances to the next
ingredient once the motion, tolerance, and
delay time requirements have been met.

Using Tolerance:

The Tolerance feature is a "tolerance window"
for the preset ingredient during batching. For
example, if the tolerance is set to 5 (%) and
the preset is 1000, the "tolerance window" is
±50. So the scale is in the "tolerance window"
when the display is between 50 and -50.

The auto-advance circuitry of the recipe
function activates the "delay time" counter
while the weight is in the "tolerance window".
The alarms sound continuous at this time and
the preset is considered active. This allows the
operator to slightly "under or over shoot" an
ingredient amount and still automatically
advance to the next ingredient. The auto-
advance circuitry resets the "delay time"

detection" also resets the "delay time"
counter.

If the tolerance for that ingredient is exceeded,
the message " OVER " is displayed alternately

or [INGR.#] to advance to the next ingredient.

Setting tolerance to " OFF" allows the scale to
always auto-advance after the ingredient
amount has been loaded regardless of

press and hold the [NET/GROSS] key and
then press the [ON] key. Continue holding

scale displays the message "P-ALM" followed