MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14

66

Command

Response Code

No.

Description

Code

Class

Description

50

Read Dynamic Variable

Assignments

0

1-5

6

7-15

16

17-127

Success

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

Access Restricted

Undefined

51

Write Dynamic Variable

Assignments

0

1

2

3-4

5

6

7

8-15

16

17-31

32

33-127

Success

N/A

Error

N/A

Error

Error

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Undefined

Access Restricted

Undefined

Busy

Undefined

53

Write Device Variable Units

0

1-4

5

6

7

8-10

11

12

13-15

16

17-31

32

33-127

Success

N/A

Error

Error

Error

N/A

Error

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Undefined

Invalid Device Variable Code

Invalid Units Code

Undefined

Access Restricted

Undefined

Busy

Undefined

54

Read Device Variable Information

0

1

2

3-4

5

6

7-15

16

17-31

32

33-127

Success

N/A

Error

N/A

Error

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Access Restricted

Undefined

Busy

Undefined

56

Write Device Variable Transducer

Serial No.

0

1

2

3-4

5

6

7

8-15

16

17-31

32

33-127

Success

N/A

Error

N/A

Error

Error

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Undefined

Access Restricted

Undefined

Busy

Undefined

59

Write Number of Response

Preambles

0

1-2

3

4

5

6

7

8

9-15

16

17-31

32

33-127

Success

N/A

Error

Error

Error

Error

Error

Warning

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Passed Parameter Too Large

Passed Parameter Too Small

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Set to Nearest Possible Value

Undefined

Access Restricted

Undefined

Busy

Undefined

60

Read Analog Channel and

Percent of Range

0

1

2

3-4

5

6

7

8

9-15

16

17-127

Success

N/A

Error

N/A

Error

Error

N/A

Warning

N/A

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Update Failure

Undefined

Access Restricted

Undefined