MX/QX HART Field Unit FCD LMENIM2340-00 – 1/14

flowserve.com

Command

Response Code

No.

Description

Code

Class

Description

91

Read Trend Configuration

0

1-4

5

6

7-10

11

12-127

Success

N/A

Error

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Invalid Trend Number

Undefined

92

Write Trend Configuration

0

1

2

3

4

5

6

7

8

9-10

11

12-15

16

17

18-127

Success

N/A

Error

Error

Error

Error

Error

Error

Warning

N/A

Error

N/A

Error

Error

N/A

No Command-Specific Errors

Undefined

Invalid Selection

Passed Parameter Too Large (trend update period)

Passed Parameter Too Small (trend update period)

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Set to Nearest Possible Value (trend update period)

Undefined

Invalid Trend Number

Undefined

Access Restricted

Invalid Device Variable Index

Undefined

93

Read Trend

0

1-4

5

6

7

8

9-10

11

12-127

Success

N/A

Error

Error

N/A

Warning

N/A

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

Undefined

Trend not Active

Undefined

Invalid Trend Number

Undefined

95

Read Device Communications

Statistics

0

1-5

6

7-127

Success

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

103

Write Burst Period

0

1-4

5

6

7

8

9

10-15

16

17-31

32

33

34

35

36

37-127

Success

N/A

Error

Error

Error

Warning

Error

N/A

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Update Times Adjusted

Invalid Burst Message

Undefined

Access Restricted

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

104

Write Burst Trigger

0

1-2

3

4

5

6

7

8

9

10

11

12

13

14-15

16

17-31

32

33

34

35

36

37-127

Success

N/A

Error

Error

Error

Error

Error

Warning

Error

N/A

Error

Error

Error

N/A

Error

N/A

Error

Error

Error

Error

Error

N/A

No Command-Specific Errors

Undefined

Passed Parameter Too Large

Passed Parameter Too Small

Too Few Data Bytes Received

Device-Specific Command Error

In Write Protect Mode

Burst Condition Conflict

Invalid Burst Message

Undefined

Invalid Device Variable Classification

Invalid Units Code

Invalid Burst Trigger Mode Selection

Undefined

Access Restricted

Undefined

Busy

DR Initiated

DR Running

DR Dead

DR Conflict

Undefined

105

Read Burst Mode Configuration

0

1-5

6

7-8

9

10-31

32

33-127

Success

N/A

Error

N/A

Error

N/A

Error

N/A

No Command-Specific Errors

Undefined

Device-Specific Command Error

Undefined

Invalid Burst Message

Undefined

Busy

Undefined

Advertising