7-3 onboard super io function – Jetway Computer J7F2 User Manual

Page 36

Advertising
background image






32

3-7-3 Onboard Super IO Function

Phoenix – AwardBIOS CMOS Setup Utility

Onboard Super IO Function

Item Help

Onboard FDD Controller Enabled

Onboard Serial Port 1 3F8/IRQ4

Onboard Serial Port 2 2F8/IRQ3

VART Mode Select Normal

Onboard Parallel Port 378/IRQ7

Parallel Port Mode SPP

ECP Mode Use DMA 3


Menu Level >>

↑↓→← Move Enter:Select Item +/-/PU/PD:Value F10:Save ESC:Exit F1:General Help

F5:Previous Values F6:Optimized Defaults F7:Standard Defaults

Onboard FDD Controller
Select Enabled if your system has a floppy disk controller (FDD) installed on the system board and
you wish to use it. If you install add-on FDC or the system has no floppy drive, select Disabled in
this field. The settings are: Enabled and Disabled.

Onboard Serial Port 1/Port 2
Select an address and corresponding interrupt for the first and the second serial ports. The settings
are: 3F8/IRQ4, 2E8/IRQ3, 3E8/IRQ4, 2F8/IRQ3, Disabled, Auto.

Onboard Fast IR
This item allows you to Enabled Fast InfraRed (IR) function of the onboard I/O chip, when enabled
this function user must install driver the driver is in CD Pack\VIA\VIAFIR.

Onboard Parallel Port
There is a built-in parallel port on the on-board Super I/O chipset that Provides Standard, ECP, and
EPP features. It has the following option:

Disabled

(3BCH/IRQ7)/

Line Printer port 0

(278H/IRQ5)/

Line Printer port 2

(378H/IRQ7)

Line Printer port 1

Parallel Port Mode

SPP

: Standard Parallel Port

EPP

: Enhanced Parallel Port

ECP : Extended Capability Port
SPP/EPP/ECP/ECP+EPP
To operate the onboard parallel port as Standard Parallel Port only, choose “SPP.” To operate
the onboard parallel port in the EPP modes simultaneously, choose “EPP.” By choosing “ECP”,
the onboard parallel port will operate in ECP mode only. Choosing “ECP+EPP” will allow the
onboard parallel port to support both the ECP and EPP modes simultaneously. The ECP mode
has to use the DMA channel, so choose the onboard parallel port with the ECP feature. After
selecting it, the following message will appear: “ECP Mode Use DMA” at this time, the user can
choose between DMA channels 3 to 1. The onboard parallel port is EPP Spec. compliant, so
after the user chooses the onboard parallel port with the EPP function, the following message will
be displayed on the screen: “EPP Mode Select.” At this time either EPP 1.7 spec. or EPP 1.9
spec. can be chosen.


Advertising