Testing the optical interface port

Selecting the "1:OPTICAL" on the TEST COMMU-
NICATION menu calls up the screen shown at left.

At the slave BHT-7000 to be tested, select the
"1:SLAVE" and at the master BHT-7000, select the
"2:MASTER."

During the test, the screen shown at left is dis-
played.

If any error occurs, the tested slave BHT-7000 beeps
three times and shows the screen at left.

In parentheses are error codes which have the
following meanings:

(X X)

1: The received data is different from

the sent data.

2: A timeout has occurred during

standby for data reception.

1: 2400 bps
2: 9600 bps
3: 115200 bps

Press the C key to return to the TEST COMMUNI-
CATION menu.

The master BHT-7000 will automatically return to
the TEST COMMUNICATION menu after 10 sec-
onds from the occurrence of an error.

Upon normal completion of the test, the tested
slave BHT-7000 beeps once and shows the screen
at left.

Press the C key to return to the TEST COMMUNI-
CATION menu.

The master BHT-7000 will automatically return to
the TEST COMMUNICATION menu.

TEST COMMUNICATION
< OPTICAL >

1:SLAVE

2:MASTER

TEST COMMUNICATION
< OPTICAL >

** Testing **

TEST COMMUNICATION
< OPTICAL >

** Test NG **
(XX)

TEST COMMUNICATION
< OPTICAL >

** Test OK **