MPS-3111 Series SLA Power Supply Operations Manual Supplement, Doc. No. L01-506

31

InterMetro Industries Corporation

Problem

Checks

• Replace the battery:

o If the battery has been in service for a long period

of time or been subjected to a significant number
of discharge cycles, it may not be capable of
holding a charge.

o If the battery has experienced a significant deep

discharge, such as leaving the power supply
switch “ON” when not used for a long period of
time (see “Extended Storage” above), it may be
damaged.

• If this problem continues, contact InterMetro

Customer Service.

Operation on battery is
unexpectedly short.

• Unplug the unit from AC mains and check the charge

level on the Remote Fuel Gauge: the battery may
simply require a full charge cycle.

• With the power supply plugged in, check the charge

status indicators to see if the unit appears to be
charging normally (see “Remote Fuel Gauge” section
above).

• Replace the battery:

o If the battery has been in service for a long period

of time or been subjected to a significant number
of discharge cycles, it may not be capable of
holding a charge. Typical battery manufacturer
manuals recommend replacing battery when can
only get approximately 80% of rated life from it.

o If the battery has experienced a significant deep

discharge, such as leaving the power supply
switch “ON” when not used for a long period of
time (see “Extended Storage” above), it may be
damaged.

• Has any equipment been added to or changed on the

workstation?

o Additional equipment increases power draw from

the battery and shorter life.

o If workstation settings have changed (such as

monitor brightness) from recommended
specifications, battery life may be shortened.

• If this problem continues, contact InterMetro

Customer Service.