4-8

4.3.3 The Maximum Combined Simultaneous Power Consumption




Never exceed the maximum combined simultaneous power consumption.

The following chart shows the maximum power available from the 120V-20A GFCI receptacles during
simultaneous consumption (main terminals and receptacles) for both single or three phase settings.
Values shown in the left column give the maximum current available at the 120V-20A GFCI
receptacles compared to the value of the simultaneous current consumption from the main terminals.

SDG40S-8B1 SDG45S-8B2

Single Phase

120V-20A

GFCI Rcept.

Three Phase

240/480V

Single Phase

240/120V

Three Phase

240/480V

Single Phase

240/120V

kW kVA

kVA kVA kVA

0.0 38.0

22.0 45.0 26.0

1.2 33.8

20.8 40.9 24.8

2.4 29.7

19.6 36.7 23.6

3.6 25.5

18.4 32.6 22.4

4.8 21.4

17.2 28.4 21.2

4.4 Engine OilCoolantFuel

4.4.1 Engine Oil



Viscosity of engine oil greatly affects startability, performance, oil consumption of the engine, as
well as wear of the moving parts.



Choose appropriate oil based upon the table below according to the outside air temperature.



Use engine oil recommended by us.

Classification

API service classification CF class or higher

Viscosity SAE10W-30



Be sure to use CF class engine oil or superior class. (Using engine oil with poor quality may
shorten the life of the engine).



Follow the designated regulations to dispose of engine oil.

Unit is delivered ex. factory, filled with engine oil recommended by engine manufacturer.