5. Periodic Inspection/Maintenance

5-13

A080466-2

5.5.17 Check vibration isolator rubbers

[Every 1 year or every 1,000 hours]



The vibration isolation rubber “1” is used for the

support of generator and engine. Check the rubber
for any damage or deterioration due to oil sticking.

5.5.18 Check each rubber hose

[Every 1 year or every 1,000 hours]

Check all the rubber hoses for being hardened, crack and fissure.



If any hardening, crack or fissures are found on each hose (air filter, radiator, fuel and drain)

replace it by a new one.



Check each clip fixing the hoses and if any loosened hose is found, retighten it.



Even before the periodical internal comes, replace it if any hardening, any cracks are found.

When replacing it, please contact our branch office or your distributor.

5.5.19 Check and change engine fuel hose

[Check every 50 hours / Change every 2 years ]



Rubber hoses become hardened or deteriorated, replace them even before the specified hours or

periodical intervals.



Ask your nearest dealer for its replacement.