4. Operation

4-10

4.5.3 Check Fuel

Before starting operation, make sure to check the level of residual fuel so that fuel shortage

during operation can be avoided.

If necessary, drain condensate accumulated at the bottom of the fuel tank.

Do not, under any circumstance, bring lit cigarettes and/or matches
to the fuel.

The fuel is extremely flammable and dangerous. Be careful of fire
because it is very likely to catch fire.

Refuel only after stopping the engine, and never leave open fuel can
near the machine. Do not spill. It could cause a fire. When it is spilt,
wipe it up completely.

Refilling fuel tank should be done in an outdoor well-ventilated place.

Do not supply fuel up to the fuel cap. And then the fuel may get spilt
when the unit is moved, transported and it is vibrating.

4.5.4 Check for Water separator

The water separator is installed at the bottom of the fuel pre-filter

Procedures>

It is possible to judge the water level and amount of
sediment by looking through transparent cap“1”.If there
is any water or sediment collected at the bottom,set a
container to catch the drain water under drain valve“2”.

Lossen drain valve“2”and drain the water.

Tighten drain valve “2” immediately after fuel oil begins

to be drained.

Drain the condensate in container, and then dispose of
condensate according to the designated regulations.





4.5.5 Cleaning the instruments inside control panel

Before starting operation, open control panel and

check each breaker,

terminal plate and each

controller for any dust, sand and dirt accumulated.

If the machine is operated with such dust, sand and

dirt sticking, it could cause malfunction and trouble

of instrumentation. If any, stop the machine, and
clean them by blowing compressed air. when doing
cleaning job, wear protection glasses.

D004

Fire prevention

A080102

1

2

A080139

Air blow

Control panel