1.Safety

1-6

SY001

TR0304

W009

W003

1.3 Cautions during Inspection and Maintenance



Before starting inspection, switch off the circuit breaker of this
machine, remove the starter key from the starter switch, and
then hang a “Now Checking and under Maintenance” tag
where it can be easily seen. The checker must keep the key
during checking and maintenance.

Remove the negative (–) side cable from the battery.
If the above procedure is neglected, and another person starts
operating the machine during check or maintenance, it could
cause serious injury.



Be sure to stop the engine and remove the starter key
whenever the tension of the fan belt is to be adjusted.

If the machine is running, it might catch the operator’s hand
into the fan belts, and this could cause a serious injury.






Be sure to stop the engine and remove the starter key
whenever the tension of the fan belt is to be adjusted.

If the machine is running, it might catch the operator’s hand
into the fan belts, and this could cause a serious injury.







When cleaning dust accumulated in such devices as the
air-filter, etc., by blowing compressed air, wear safety glasses,
etc. to protect your eyes.




Hang a “Now Checking and under Maintenance” tag

Adjusting tension of fan belt

Hands off from cooling fan

Cleaning by air-blow