7. Storage of the Unit

7-1

7.1 Preparation for Long-term Storage

When the unit is left unused or not operated longer than half a year (6 months), store it at the dry
place where no dust exists after the following treatments have been done to it.

Put the unit in a temporary cabin if it is stored outside. Avoid leaving the unit outside with a
sheet cover directly on the paint for a long time, or this will cause rust to the unit.

Perform the following treatments at least once every three months.


<Procedure>

Discharge existing lubricant from the engine oil pan. Pour new lubricant in the engine to clean
its inside. After running it for a while, drain it again.

Spread lubricant on each moving part.

Completely charge the battery and disconnect grounding wires. Remove the battery from the
unit, if possible, and store it in a dry place. (Charge the battery at least once every month.)

Discharge coolant and fuel from the unit.

Seal air-intake port of engine and other openings like the muffler with a vinyl sheet, packing
tape, etc., to prevent moisture and dust from getting in the unit.

Measure the insulation resistance of the generator, and make sure that it is more than 1MΩ.
(See 5.5.3)

Be sure to repair any trouble and maintain the unit so that it will be ready for the next
operation.