2 protection device, Operation – MMD Equipment 150S-6A6 User Manual

Page 30

Advertising
background image

4. Operation

4-3

4.2 Protection device

For prevention of troubles during operation, this machine is provided with various protection devices. If

the engine should shut down or circuit-breaker should trip owing to functions of the protection devices,

make sure to check and remove such cause of trouble. Then start operation again.

4.2.1 Warning and Emergency Display lamp



When the warning lamp glows, stop the machine immediately and take appropriate measures
to recover the situation.

Item Trouble

Measures

Monitor

Engine oil

pressure

This lamp goes on when engine oil
pressure drops during operation and

emergency stop is actuated. This lamp

lights off after engine stops.

Operating pressure: lower than 30psi

(0.2MPa)

Coolant

temperature

This lamp goes on when coolant temp.

rises. If coolant temp. rises more, engine

takes emergency stop. When coolant

temp. drops, this lamp lights off.

Temp. of lamp on:230°F(110℃)

Temp. of emergency stop:235°F(113℃)

Temp. of lamp off:228°F(109℃)

Overcrank

This lamp goes on when operator fails to
start engine, during automatic operation

mode.

Air filter

When air filter gets clogged and

differential pressure rises, lamp goes on.

Actuating differential pressure : more

than 0.9psi(6.2 kPa)

Diagnostic

lamp

This lamp blinks when engine trouble
happens. Then, a pattern of lamp signals

changes if “DIAGNOSTIC BUTTON” is

pushed. The pattern of lamp signals shows

what’s kind of trouble happens. Refer to

“OPERATOR’S MANUAL”(P37).

See 6.2

Troubleshooting

Warning and Emergency Display

Advertising