1.Safety

1-6

1.3 Cautions during Inspection and Maintenance

Hang a “Now Checking and under Maintenance” tag

Before starting inspection, switch off the circuit breaker of this

machine, remove the starter key from the starter switch, and

then hang a “Now Checking and under Maintenance” tag

where it can be easily seen. The checker must keep the key

during checking and maintenance.

Remove the negative (–) side cable from the battery.

If the above procedure is neglected, and another person starts

operating the machine during check or maintenance, it could

cause serious injury.

Be sure to stop the engine and remove the starter key

whenever the tension of the fan belt is to be adjusted.

If the machine is running, it might catch the operator’s hand

into the fan belts, and this could cause a serious injury.

Hands off from cooling fan

Be sure to stop the engine and remove the starter key

whenever check or maintenance work is carried out near the

cooling fan.

If the cooling fan is rotating, it may catch the operator or part of

his body into the fan, and it could cause a serious injury.

Cleaning by air-blow

When cleaning dust accumulated in such devices as the air-filter,

etc., by blowing compressed air, wear safety glasses, etc. to

protect your eyes.

Lighting apparatus

It is recommended to use a lamp with safety guard fitted where

the site is dark. Operating the machine gropingly or by relying on

one’s intuition could cause unexpected accidents.

Any lamps without safety guard are not recommended since they

can be broken and they could ignite flammables such as fuel, etc.

W009

TR0206

W003

TR0304

SY001

Adjusting tension of fan belt

Advertising
This manual is related to the following products: