Section 3: venting, Section 3-1: converting to rear vent, Installation – Montigo H34DF User Manual

Page 10

Advertising
background image

H*34DF Indoor Gas Fireplace

Page 10

XG0146 - 150204

Installation

Section 3: Venting

Montigo supplies a variety of direct venting and termination options.

The direct vent termination location MUST be selected such that

it is the highest point in the venting assembly. It should also be

selected such that it provides the shortest vent run possible. Should it

be impossible to ensure that the termination is the highest point or to

meet the venting guidelines laid out below please contact your Montigo

dealer to discuss power venting options.

NOTES FOR PLANNING VENTING:

„

Venting originates from the unit through the top or through the rear

„

Venting can terminate through the roof or through an exterior wall.

„

For a detailed diagram of allowed termination locations, see

Appendix A.

„

Once the termination location has been established, refer to the

appropriate section below for installation details

„

All fireplaces shipped from the factory are Top vent.

„

Silicone application is NOT required when joining Montigo vent

pipes and components.

Figure 9. Flue cover and collar removal, Top Vented fireplace.

Figure 9a. Flue cover and collar installation, Rear Vented fireplace.

Use the following instructions to convert an H*34DF* for Rear Vent use:

1. Remove the Rear flue cover and gasket (4" and 7") on the flue

outlet, as shown in Figure 9.

2. Next, Remove the Top flue collar's (4" and 7") on the flue outlet,

as shown in Figure 9.

3. Install the (removed) Rear flue cover and gasket material, to the

Top vent outlet. Fasten the cover with included hardware, as

illustrated Figure 9a.

4. Install the (4" and 7") collars to the rear vent outlet using the

included hardware, as illustrated Figure 9a.

4” Inner Flue Collar

7” Outer Flue Collar

Flue Gasket

Flue Cover Plate

7” Outer Flue Collar

4” Inner Flue Collar

Flue Gasket

Flue Cover Plate

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

Section 3-1: Converting to Rear Vent