H*34DF Indoor Gas Fireplace

Page 9

XG0146 - 150204

Installation

6”

Clearances

When installing a shelf over the top of the fireplaces, the following

guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 2" from the rear

of the fireplace to a wall, or any combustible materials. A clearance to

combustibles of 9" for H34DF* and a clearance to combustibles of 11"

for HC34DF* , & HL34DF* is required to the underside of any combustible

shelf materials, Figure 3.
For Top Vent applications, the minimum clearance is 2" from the rear of

the fireplace to a wall, or any combustible materials, and 17 1/2" to the

underside of any combustible shelf materials, Figure 4.
For Top or Rear Vent applications where the Minimum mantel height

is required above the fireplace, (for an alcove or low profile shelf), ALL

Materials MUST BE NON-COMBUSTIBLE, Figure 5. The minimum

clearance is 2" from the rear of the fireplace to a wall, or any combustible

materials. 1” clearance is maintained on sides and bottom of vent runs

and 2” above horizontal vent runs to any combustible material.

H34DF*

9 17 1/2 2 1

0 See Section

6: Finishing

around the

fireplace

HC34DF*

11 17 1/2 2 1

0

HL34DF*

11 17 1/2 2 1

0

Installing The Standoffs

To avoid elevated mantel temperatures, all H*34DF*-Series gas

fireplaces are required to have the supplied standoffs installed.

The fireplace is supplied with two standoffs. Bend and install these

standoffs on top of the fireplace ensuring that the height of the standoff

maintains a 6" clearance.

Figure 6. Installing the standoff's.

Installing the Nailing Flange Extension - HC34DF* Only

Once the fireplace is placed into the rough framed opening, the supplied

nailing flange extension (Part No. HC34074) must be fasten securely

into place, with nails or wood screws. as shown in Figure 7.

3”

6”

Front View Side View

Figure 7. Installing the Nailing Flange Extension, see , Figure 25a.

The supplied nailing flange extension must be placed along the top

edge of the fireplace and securely fastened in place to the combustible

wood framing.

Note: The nailing flange extension can be substituted with a piece of

NON-Combustible material of the same size and thermal characteristics,

ie: cement board or equivalent. This is recommended in applications

where the facing materials will not adhere to the metal nailing flange.

MODEL

Top - Rear V

ent

Note: Clearance from top of fireplace to a ceiling within the fireplace

enclosure.

Top - T

op V

ent

Rear

Sides

Floor

Mantel