H*34DF Indoor Gas Fireplace

Page 23

XG0146 - 150204

Installation

Side wall clearances are 3". Combustible surrounds may be installed with

3" clearance to the side of the fireplace as shown in Figure 26 or 26a.

Figure 26. H34DF* and HL34DF*Combustible surrounds.

Mantels & Surrounds
NOTE:
National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.

Figure 26a. HC34DF* Combustible surrounds.

Combustible Header

Drywall/

Sheetrock

3”

45°

6”

Combustible Header

Drywall/ Sheetrock

3”

45°

6”

3”

Nailing Flange

WARNING

Do not place any materials or objects on top of the

valve blind. Doing so could result in failure of door

relief system or heat dissipation.