H*34DF Indoor Gas Fireplace

Page 15

XG0146 - 150204

Installation

18

26

A

C

B

Acceptable

Vent run within

non-shaded area

Horizontal Run (in.)

Ve

rt

ical Height (in.)

Unacceptable Vent run

within shaded area

48

50

Figure 16. H*34DF* Rear Vent Venting Graph for wall mounted terminations,

See Figures 16a or 16b.

Figure 16b. Rear Vented, wall mounted Multi-elbow termination installation.

Multi-elbow venting Installation for H*34DF* must have a minimum vertical rise

of 50".The vent run must comply with the Venting Graph for Rear vent, wall

mounted terminations, Figure 16.

The Venting Graph
Measure the vertical height from the fireplace hearth to the centre of the

termination and the horizontal run from the fireplace flue collar to the wall

flange of the termination. Plot on the Venting Graph Figure 16 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 60" and the horizontal run to

the wall flange of the vent termination is 24", this would be an acceptable

installation.
Example B: (Acceptable Installation)
If the vertical dimension from the hearth is 78" and the horizontal run to

the wall flange of the vent termination is 60", this would be an acceptable

installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the

horizontal run to the wall flange of the vent termination is 120", this

would NOT be an acceptable installation.

Figure 16a. Straight run, Rear Vented, wall mounted termination for H*34DF*,

Figure 16.

If your installation does not fall within the

venting graph parameters, (non-Shaded

area) please contact a local Montigo

dealer for Power Venting options.

30” Max.

50” Min.

18”

Max.

Flex or Rigid

Section

24”

Min.

26”

Acceptable Vent

run within non-

shaded area.

Acceptable Vent run

within non-shaded area.

26”

MXT Extension

RHS100 Heat

Shield

Termination

Hearth

Exterior

Wall

NOTE:

18” MAX. horizontal

run with no vertical lift.

18” MAX.

Figure 15b. Top Vented, wall mounted Multi-elbow installation. See

Venting Graph for Top vent, wall mounted terminations, Figure 14 or 15.

Notes Wall Mounted Terminations: TOP VENT

„

All measurements for vertical or horizontal runs are measured

from centre of the vent pipe.

„

Venting runs must fall within the limits set by the venting graph,

see Figure 16.

„

The fireplace must be converted to Rear Vent configuration prior

to running vent, see Figure 9 and 9a.

Solid Section

Flex Section

Hearth

30”min

15’ Max.

Heat

Shield

Termination

Exterior

Wall

8' MIN

at MAX

horizontal