Service – Montigo PVVEX58-300 User Manual

Page 11

Advertising
background image

PVVEX58-300 & PVVEX510-300 Horizontal Power Vent

Page 11

XG0518 - 070714

Top Cover

Top Cover

Screws x 4 plcs

Screw Locations

x 4 plcs

Wind Baffle

Rain Skirt

Screw Locations

x 5 plcs

Top Separator

Step 1:

a) Remove the 4 outer screws

that fasten the Top Cover to

the termination

b) Remove the Cover.

PVVEX58-300

Motor Removal / Servicing

Step 2:

a) Remove the 4 outer screws

that fasten the Wind Baffle to

the termination.

b) Lower the Wind Baffle to

rest on the Rain Skirt.

Step 3:

a) Remove the 5 outer screws

that fasten the Top Separator

to the termination.

b) Remove the Top Separator.

Capacitor Removal and Servicing

Step 1: Remove the 4 outer screws that fasten the top cover to the

termination. Remove the cover.

Figure 5.

Capacitor Replacement [REC1252]
Turn off power and gas before servicing.

Figure 5a.

Step 2: Cut zap straps.

Step 3: Unscrew ground wire/capacitor bracket from motor.
WARNING: Save this screw.

Figure 5b.

Step 4: Cut brown wire from motor and black wire from capacitor.

Figure 5c.

Step 5: Cut black fibre wire from power cable and blue wire from

motor.

Figure 5d.

Service

Advertising