Step 12: Using the ground screw, screw the capacitor bracket and

the ground wire to the motor.

Step 13: Strip the ends of all the wires. Using the large bell connec-

tor, connect the white fibre wire from the power cable to the black wire

from the motor and one of the black wires from the capacitor.

Figure 6m.
Step 14: Using a small bell connector, connect the black fibre wire

from the power cable to the blue wire of the motor.

Figure 6n.

Step 15: Using the other small bell connector, connect the other

black wire from the capacitor to the brown wire from the motor.

Figure 6o.
Step 16: Using a zap strap to bundle the wires neatly together.

Figure 6p.
Step 17: Using another zap strap, secure the bundle to the capacitor.

Figure 6q.