PVVEX58-300 & PVVEX510-300 Horizontal Power Vent

Page 15

XG0518 - 070714

Step 7: Cut the white fibre wire from the power cable.

Figure 6f.
Step 8: Remove 4 screws securing the motor mounting plate.

Figure 6g.

Figure 6h.

Step 9: Lift out motor and capacitor.

REC1253

Figure 6i.
Step 10: Drop new motor assembly into the power vent and screw

with supplied 4 screws and star washers. Line up cut out in motor

mounting plate with electrical conduit.

Figure 6j.
Step 11: Remove the ground wire screw from the motor. NOTE:

Save this screw for later.

Figure 6k.