Remko rvt...dc – REMKO RVT 263 DC User Manual

Page 50

Advertising
background image

Malfunction

Possible causes

Checks

Remedial measures

The unit is running but

only provides reduced or

no cooling or heating

output.

Filter is dirty / air inlet /

outlet opening is blocked

by debris.

Have the filters been

cleaned?

Clean the filters

Windows and doors

open. Heating / cooling

load has increased

Have structural / usage

modifications been

made?

Close windows and

doors / install additional

units

Neither cooling nor

heating mode has been

set

Does the cooling symbol

appear on the display?

Correct the settings for

the unit

Fins on outdoor unit

blocked by foreign

objects

Does the fan of the out-

door unit work? Are the

exchanger fins unob-

structed?

Check the fan or winter

fan speed control,

reduce the air resistance

Leaking cooling cycle

Are there signs of frost

on the exchanger fins of

the indoor unit?

Repair by specialist

Outdoor unit iced up

Check outdoor unit. Has

the cassette probe on

the outdoor unit been

correctly positioned?

De-ice and fit the probe

at the point where the

most ice forms

Condensate discharge

on unit

Drainage pipe on collec-

tion container clogged /

damaged

Can the condensate

drain off without any

obstruction?

Clean the drainage pipe

and collection container

Faulty external conden-

sate pump or float

Is the collection tray full

of water and the pump

not running?

Call out a specialist to

replace the pump

Condensate has not

drained away and has

collected in the conden-

sate drainage line

Is there an incline on the

condensate drainage

line? Check there is no

blockage in the pipe.

Ensure there is an incline

when laying the conden-

sate drainage line and

clean the pipe.

Condensate does not

drain off

Are the condensate

drainage lines unblocked

and is there a steady

incline? Are the conden-

sate pump and liquid

level switch functioning

correctly?

Route the condensate

drainage line with an

incline and clean it. If the

liquid level switch or the

condensate pump is

defective, have them

replaced.

Float is stuck or jammed

due to excessive dirt.

Are the LEDs on the

receiver unit of the

indoor unit flashing?

Should be cleaned by

specialist firm

REMKO RVT...DC

50