FOR THE INSTALLER

1. If installing a carbonator, locate it nearby.

2. Route the drain lines to the building drain. Vent
the drain tubes if installing at the back of the
cabinet.

3. Locate electrical supply (for cord - 115v outlet).

The outlet must be properly grounded. The
circuit must be fused and no other electrical
appliance should be on the circuit.

ALL ELECTRICAL WIRING MUST CONFORM
TO NATIONAL AND LOCAL CODES

4. Remove splash panel.

Refer to the plumbing schematic on the back of
the cabinet (all stub lines are labeled) and:

A. Connect carbonated water supply lines (field
supplied) from the remote carbonator to the
carbonated water stub line at the dispenser cold
plate.

B. Connect water supply lines (field supplied)
from building source to carbonator (filtered water
is recommended).

C. Connect water supply line(s) to the plain
water stub line(s) on the cold plate for use with
the non-carbonated valve.

NOTE: If ALL valves need carbonation, connect
an additional carbonated water line from the
carbonator to the plain water stub line on the
cold plate.

D. Connect syrup lines from the syrup supply to
the cold plate syrup stub lines.

6. Connect primary CO

2

regulator to CO

2

tank.

Secure secondary regulators to wall or other
stationary surface.

7. Connect CO

2

line between outlet of primary

regulator and inlet of secondary regulators.
8. Connect CO

2

lines between outlets of

secondary regulators and syrup tanks. Or to syrup
pumps in the case of Bag-In-Box.

Back Plumbing

Cover Plate

Remove Splash

Panel and Sink

Cold

Plate

Stub

Lines

Typical Installation

Sink and

Cold Plate

Drain Tubes

Beverage &

Water Tubes

RS160 and RS220