Primary cvs, Cv 11 packet time out value, Description – SoundTraxx Tsunami Steam Technical Reference User Manual

Page 10

Advertising
background image

Tsunami Technical Reference

Page 8

CV 11
Packet Time Out Value

Description

Contains a value between 0 and 255 corresponding to the time period that is

allowed to elapse between receipts of a valid packet addressed to the DSD

before a throttle shutdown occurs.

D0-D7: Packet Time-out Value

The time out period is computed in seconds as:

Time Out Period = CV 11 X 0.25

A CV value of 0 disables the time out period and the locomotive will run

indefinitely without receiving another packet.

For all other values, the DSD maintains an internal timer, which is reset every

time the DSD receives a valid broadcast address packet or other valid packet

whose address matches its primary address or, if enabled, the extended

address or consist address.

In the event no valid packets are received within the prescribed time period,

the DSD will bring the locomotive to a stop at the rate set by CV 4 and CV

24. The state of the auxiliary function outputs will remain unchanged.

Default value:

0

Bit 7

Bit 0

D7

D6

D5

D4

D3

D2

D1

D0