CV 95
Reverse Trim

Description

Contains a value, n, between 0 and 255 that specifies a scaling factor

interpreted as n/128 by which the reverse drive voltage is multiplied.

D0-D7:

Reverse Trim Scalar

The reverse trim scalar allows the decoder’s overall throttle response in the

reverse direction to be adjusted up or down for the purpose of matching one

locomotive’s speed curve to another.

A trim value of 128 (0x80) yields a scaling factor of 1.0 which will have no net

effect on the speed response.

Trim values between 129 and 255 (0x81-0xFF) have the effect of increasing

the motor voltage by a factor ranging between 1.01 to 1.99.

Trim values between 1 and 127 (0x01-0x7F) will decrease the motor voltage

by a factor between 0.008 and 0.99.

A trim value of 0 disables the trim scalar computation.

This CV is used only when speed tables are enabled (CV 29, Bit 4 = 1).

Otherwise, this CV will have no effect.

Default Value:

128

Related CVs:

See also Forward Trim CV 66, CV 25, CV 29.